1. Product Overview
The drill floor manifold is used for distribution, connection, and control of high-pressure drilling fluid and service fluids in the drill-floor area and is an important part of the drilling manifold system.
Working pressure is 5,000 psi to 15,000 psi, nominal bore is 2 in to 3 in, and temperature class is -29 ℃ to 121 ℃.
It is suitable for standard and sour service and can meet relevant NACE MR0175 requirements.
2. Design Features
The compact structure, small size, and light weight make transportation and drill-floor installation convenient.
Union connections allow quick installation and dismantling and can reduce field operation labor intensity.
Selection can be made according to drill-floor space, line routing, and pressure rating.
3. Drill Floor Manifold Main Technical Parameters
| Specification / Model | Cold Working Pressure | Choking Method | Connection Type |
|---|---|---|---|
| ZTG-70-2 | 10,000 psi | Two positive choke valves | Union connection |
| ZTG-70-2F | |||
| ZTG-105-2 | 15,000 psi | ||
| ZTG-105-2 | One positive choke valve and one manual choke valve | ||
| ZTG-70-3 | 10,000 psi | ||
| ZTG-70-3F | |||
| ZTG-105-3 | 15,000 psi |